• Precision control valves

FUJIKURA ®
Type

RT
E/P-8-2

RT
I/P-8-2
RT
E/P-2-2
RT
I/P-2-2
RT
E/P-1-2
RT
I/P-1-2
Description
Power fluid air 
Range of pressure kgf / cm2 (kpa)

0.2~8.4[20~840]

0.4~2.1[40~210]

0.2~1.0[20~100]

Inlet pressure rangekgf / cm2 (kpa) max   min

9.9(990)
0.35(35)

7.0(770)
0.2(35)
 
Inlet pressnre range
Volt(VDC)

0~10

--------- 0~5 --------- 0~10 ---------
Inlet

805

--------- 530 --------- 805 ---------
current (mADC) ---------- 4~20 --------- 4~20 --------- 4~20
Inlet ---------- 260 --------- 220 --------- 180
  Linearity                            % F.S.   1.5 1.0
  Hysteresis                          % F.S.   10
  Repeatability                     % F.S.   ∮0.1 0.5
  Step Response                   (Sec)  1.0 or less 0.3 or less 0.2 or less
  Span Adjust Range            kgf / cm2 (kpa)  6.5[650] 2.4[240] ---------
  Relief Sensitivity                kgf / cm2 (kpa) pressure set 0.01[1] or less
Air consumption(Nl/min) 3.7 4.8
Range of temperature(C) 5~60
Connect(PT) 1/4
pressure gauge port size(PT) 1/4
Weight(kgf) 0.94



General parameters Pneumatic parameters
Cat. No. : (without connector) 4088110.7040 Medium:

Filtered, lubricated or

non-lubricated air

Cat. No. :(with protection(Ex)s G4 4088110.7044

Operating pressure

range pe(bar)

0-10
Designation: 3-way pressure reducing valve 0.2
Symbol:

Switching time(ms)

0          Pv:

Pvmax:   0:

20

30

Design: Poppet valve, direct controlled Hysteresis  % Pmax

with dither 30% 100 Hz:

<5
Line connection: R 1/8 Reproducibilty % Pmax: <1
Mounting position: Vertical Linearity See characteristic curve
Flow direction: Determined Sensitivity of response % In: 1
Actuation: Proportional solenoid Electric parameters
Weight                              (kg): 0.85 Rated voltage Vrated(V): 24VDC
Ambient temperature         n[C] -10 to +40 Rated current Irated(mA): 800
Nominal size: 4 Output W 22



Standard Equipment Precision Air Regulator Precision Control Valves